EN
News News
News
HomeNewsTHE SCIENCE BEHIND EFFICIENT COMFORT: MENRED UNDERFLOOR HEATING SYSTEM TECHNOLOGY
HomeNewsTHE SCIENCE BEHIND EFFICIENT COMFORT: MENRED UNDERFLOOR HEATING SYSTEM TECHNOLOGY

THE SCIENCE BEHIND EFFICIENT COMFORT: MENRED UNDERFLOOR HEATING SYSTEM TECHNOLOGY

Date:2025/12/8 16:40:41     Click:21

 

UNDERFLOOR HEATING SYSTEMS have evolved from simple pipe networks to sophisticated climate control solutions. MENRED's latest generation floor heating technology incorporates gradient temperature field design that fundamentally changes how warmth is distributed through living spaces.

 

Technical Breakthrough: Gradient Temperature Field

Traditional floor heating often creates "hot spots" near pipes and "cold zones" between circuits. Our patented solution (Patent No. CN202310845XXX) uses computational fluid dynamics-optimized pipe layouts combined with variable flow rate controls to maintain surface temperature variations below 1.5°C across the entire floor area.

 

System Components and Specifications:

PEX-Aluminum Composite Pipes:

  • Oxygen barrier layer: EVOH thickness 0.2mm
  • Operating pressure: 6 bar at 95°C
  • Thermal conductivity: 0.45 W/(m·K)
  • Expected service life: >50 years

 

Smart Distribution Manifolds:

  • Individual loop temperature control
  • Flow rate monitoring accuracy: ±2%
  • Leak detection sensors integrated
  • WiFi/Bluetooth connectivity

 

Insulation Systems:

  • Thermal resistance: R-value ≥1.5 m²K/W
  • Moisture resistance: ≤0.5% water absorption
  • Fire rating: Class A1 non-combustible

 

Performance Data from Laboratory Testing:

  • Extensive testing at our CNAS-certified laboratory demonstrates remarkable efficiency:
  • Heat-up Time: Rooms reach set temperature 40% faster than conventional systems
  • Vertical Temperature Gradient: Maintains ≤2°C difference between floor and 1.7m height
  • Energy Consumption: 38-42% reduction compared to radiator systems
  • Surface Temperature Uniformity: 95% of floor area within ±1°C of target temperature

 

Installation Advantages:

  • The modular design allows installation in various scenarios:
  • New Construction: Complete system integration during building phase
  • Retrofit Projects: Low-profile solutions (total height increase: 15mm)
  • Partial Installation: Room-by-room implementation without system compromise

 

Comparative Analysis with Traditional Heating:

Parameter

MENRED System

Conventional Radiators

Improvement

Energy Use

62 kWh/m²/year

105 kWh/m²/year

41%

Response Time

20-30 minutes

60-90 minutes

67% faster

Temperature Uniformity

±1°C

±4°C

400% better

Maintenance Needs

Every 10 years

Annual

90% reduction

 

+86 19063977724 +86 15216267257 mkt@menred.com